Unshielded aluminum high voltage cables for hybrid and battery vehicles.
Conductor cross-sections can be optimized thanks to our Coroflex high-voltage cables - because they are suitable for rated voltages of up to 600 volts a.c. / 1,000 volts d.c. and withstand temperatures of up to 180 °C. With our simulation capabilities, we are able to calculate conductor heating as a function of current loads and operating ambient temperatures. Our derating simulations enable you to define your optimum conductor cross-sections - and thus reduce weight, packaging space and costs.
Coroflex | CORES | CORE | RESISTANCE (d.c. 20 °C) (max.) | CABLE WEIGHT | ||
---|---|---|---|---|---|---|
TYPE NO. | NO. | SIZE | DIAMETER [mm] | CONDUCTOR [mΩ/m] | approx. [g/m] | |
9-2635 | 1 x | 10 mm² | 6.50 | -0.6 | 3.03 | 47 |
9-2635 | 1 x | 12 mm² | 7.20 | -0.6 | 2.53 | tbd |
9-2635 | 1 x | 16 mm² | 8.30 | -0.6 | 1.93 | 81 |
9-2635 | 1 x | 20 mm² | 8.70 | -0.6 | 1.59 | tbd |
9-2635 | 1 x | 25 mm² | 10.00 | -0.6 | 1.24 | 115 |
9-2635 | 1 x | 30 mm² | 10.40 | -0.7 | 1.08 | tbd |
9-2635 | 1 x | 35 mm² | 11.00 | -0.7 | 0.878 | 150 |
9-2635 | 1 x | 40 mm² | 11.90 | -0.7 | 0.788 | tbd |
9-2635 | 1 x | 50 mm² | 13.20 | -0.8 | 0.613 | 215 |
9-2635 | 1 x | 60 mm² | 14.20 | -0.8 | 0.525 | tbd |
9-2635 | 1 x | 70 mm² | 15.10 | -0.8 | 0.432 | 270 |
9-2635 | 1 x | 85 mm² | 16.20 | -1.0 | 0.365 | 302 |
9-2635 | 1 x | 95 mm² | 17.40 | -1.0 | 0.327 | 363 |
9-2635 | 1 x | 120 mm² | 19.50 | -1.0 | 0.255 | 461 |